Ahspl. comprises of two major business segments - in vitro Diagnostics Products & consumable & Blood banking equipments with consumables. AHSPL. offers products and servies to a range of industries including blood bank, in-vitro diagnostic facilities in clinical labs. hospitals, nursing homes & laboratories.Innovation, ethical practice and dedicationhave helped to unlock our potential we have been attaininig excellence and success through term work as the four business segment move ahead in unison towards the common goal of creating sustainable competencies in their respective business areas.

REVERSE PASSIVE HAEM AGGLUTINATION TEST :
Hepa S-Ag is based on RPHA technology in which Anti-HBs sensitized sheep erythrocytes are used as capture Antibodies.
DETECTION OF Ad & Ay SUBTYPES :
Hepa S-Ag kit is able to detect all Ad & Ay subtypes of HBsAg.
ACCURATE:
Detection limit is 20 ng/ml.
HIGHLY SPECIFIC :
The phosphate buffered saline in Hepa S-Ag contains 3% of soluble sheep erythrocyte stroma and several other components to prevent non-specific agglutination.
HIGH CORRELATION :
The test method is found to be well correlated with the RIA and EIA test method.
SAFE:
The positive control provided in the kit is heat treated at 60 °C for 10 hours for prevention of occupational hazards of transmission of hepatitis B infection.
CONVENIENT :
Total assay procedure of only 120 minutes.

3rd GENERATION ASSAY :
GENEDIA HCV ELISA 3.0 is based on indirect ELISA principle.The microwells are coated with HCV recombinant core & NS-3 antigens alongwith synthetic peptides including core, NS-4 & NS-5.
EFFICIENT DETECTION :
Due to the combination of synthetic peptides and recombinant antigens, GENEDIA HCV ELISA 3.0 detects HCV antibodies more efficiently than kits employing any one of the technologies.
PRECISE :
99.5% sensitivity for anti HCV ANTIBODY.
HIGH SPECIFICITY :
99.6% Specificity is achieved by use of defined recombinant antigens & Synthetic peptides as capture antigens.
CONVENIENT :
Total assay procedure of only 120 minutes

3rd GENERATION ASSAY :
GENEDIA HBsAg ELISA 3.0 is based on direct ELISA principle. The microwells are coated with Monoclona l Anti-HBs Antibodies, the HRPO conjugate is composed of HRPO conjugated with Anti-HBs Antibodies.
DETECTION OF Ad & Ay SUBTYPES :
The advanced affinity purification technology employed in purifying Anti-HBs Antibodies coated on microwells of GENEDIA HBsAg ELISA 3.0 enables the kit to detect all Ad & Ay subtypes of HBsAg.
ACCURATE:
Detection limit is 0.2 ID/ml (WHO HBsAg standard)
HIGH SPECIFICITY :
99.9% Specificity by use of defined & highly purified anti-HBs Antibody.
CONVENIENT :
Total assay procedure of only 120 minutes.

3rd GENERATION ASSAY :
GENEDIA HIV 1/2 ELISA 3.0 is based on direct ELISA principle.
DETECTION OF SEROCONVERTORS :
GENEDIA HIV 1/2 ELISA 3.0 is able to detect IgM and IgG antibodies against HIV 1 &tor HIV 2 simultaneously.
ACCURATE :
100% sensitivity for anti HIV 1/2 antibody.
HIGH SPECIFICITY :
99.9% Specificity due to use of defined recombinant antigens : p24 & gp41 for HIV 1 & gp36 for HIV 2
CONVENIENT :
Total assay procedure of only 120 minutes

How to screen Anaemia in the obsence of Laboratory-based haemoglobinometry
Sensitivity and specificity of the Scale to screen for anaemia
For severe anaemia, the Scale shows a sensitivity of 95% and a specificity of 99.6%. To distin¬guish
normal from mild anaemia, the sensitivity and specificity are 98% and 86% respectively, results that are well above the reliability of any clinical measurement. Using a photometer (HemoCue®) as a reference, the Scale was compared with the copper sulphatespecific gravity method that is traditionally used to screen blood donors for anaemia. The scale was accurate to 98% in distinguishing among 2,800 volunteer blood donors those with normal Hb from those rejected because of anaemia. The Scale was more reliable than coppersulphate, the tests giving 2.4% and 5.4% false readings respectively. Moreover the copper sulphate presents a potential environmental hazard in the disposal of used solutions. The idea is not new. Tallqvist, among others, tried in vain as long ago as 1900 to substantiate the theory that the colour of a drop of blood could reliably indicate anaemia. The colour printing technology and test-strip paper available at that time were such that the results were inaccurate and the concept shelved. It has taken modern technology to perfect the material on which blood can be absorbed, and computerized spectrometric analysis to identify colours that can accurately match shades ofhaemoglobin at different concentrations. Following many years of development by WHO, the Haemoglobin Colour Scale is now available as a simple and effective medical device for theaccurate estimation of haemoglobin levels in blood.The Kits are available at presentin English and markings French language, other languages upon request.The price level per single test is lower than the onefor other existing test methods.For exact prices, for detailed purchase conditions and all other additional information you may need, please contact us. Depending on the final destination, we will either contact youdirectly or pass you on to our nearest distributor
The STARTER KIT Basic
contains:
-1 Cover-Box with dispenser
box with 200 test-stripes,
Colour Scale in a booklet
and instruction manual
(without outer packing)
The STARTER KIT contains: -1 Cover-Box with dispenser box with 200 test-stripes, Colour Scale in a booklet and instruction manual -
4 refill dispenser with each 200 paper
stripes packed in one carton box with
product and manufacturer data
For purchasing the test-stripes
only, a REFILL KIT is available,
containing:
-10 Refill dispensers with each
200 test-stripes
packed in one carton box with
product and manufacturer data
markings

( FT-2 is a quick, simple and reliable manual photometer for clinical chemistry and immunological assays.Due to its sophisticated tech* Joay the instrument is fully programmable and user-friendly.The dedicated microprocessor gives the opportunity to display the graphics of the* reaction development in the kinetic assays and the print-out of the calibration curve for the immunological tests. The FT-2's high versatility allows the measurement through the flowcell or by direct reading of thecuvettes,

Flexible
  • Alternate between whole blood and predicted samples, with the touch of a button
  • Small 12uL sample size allows analysis from venous or capillary blood collections
  • Two reagent packaging configurations to meet your laboratory's workload needs
Reliable
  • Simple system design for maximum up-time
  • Complete reagent system with market-specific quality control products developed for maximum performance
  • Authentic COULTER technology: Triplicate counting, proven COULTER histogram differential, patented sweepflow technology and extended platelet counting provide accurate results
  • Results available in less than 60 seconds

Portable.
The STAT-Site® NT9" is a battery operated, completely portable hemoglobin analyzer that fits in the palm of your hand. Finally, point-of-care testing right at your patient's side.
Advanced.
The STAT-Site® WT9" uses state-of-the-art electronics designed for optimum performance and reliability. Self-prompting graphics guide you through the simple test procedure. It even includes a "Last Result" feature that allows you to recall the last hemoglobin result.
Simple.
Hemoglobin testing is quick and easy—reducing personnel training and improving performance. Unlike competing systems, the STAT-Site8 MH9b is virtually maintenance-free.
Powerful.
With one single drop of fingerstick blood, the STAT-Site® M"9" system provides precise
hemoglobin analysis in seconds. Treatment can begin immediately, improving patient
outcomes and lowering costs.
Address : 101 A, Kundan Kutir Ashram,
Near Delhi - 110014
Phone : + 91 - 11 - 26343555
Telfax : + 91 - 11 - 26343091 - 92